New Trend Electrical Appliance Group Co., Ltd.

 Products >>Construction Electrical >> Others & Accessories >> Fuses

Item No : Fuses
Name : Fuses
Type : Building Accessory
Description :

RT16(NT)Series knifecontactor fuse
RT16-00C(NT00C)
RT16-00(NT00)
RT16-0(NT0)
RT16-1(NT1)
RT16-2(NT2)
RT16-3(NT3)
RT16-4(NT4)
RT16-00
SIST101
RT16-0
SIST160
RT16-1
SIST201
RT16-2
SIST401
RT16-3
SIST601
RT16-4
SIST1001
RT16(NT)
Scope of application
     It is applicable indusrtial electrial distributing installation of AC50Hz(or60Hz)rated voltage 500/690V and 400V,rated current 1250A and below.It is provided with the fenction of the protection against overload or short eircuit.
Type and meaning
Main technical parameter
Type Rated voltage Rated cuttent  Rated breaking capacity Rated power dissipation of fuse-link Weight of base Weight of fuse-link
Base Fuse-link  500V 690V COSφ
RT16-00 500V

690V

 

160 2,4,6,8,10,12,16,20,
25,32,40,50,63,80,100
120 50 0.1~0.2 ≤12 200 170
125,160  -
RT16-0 160 2,4,6,8,10,12,16,20,25,
32,40,50,63,80,100
50 ≤25 300 280
125,160  -
RT16-1 250 80,100,125,160,200 50 ≤32 700 450
250  -
RT16-2 400 125,160,200,250,315 50 ≤45 1150 660
400  -
RT16-3 630 315,400,500 50 ≤60 1280 850
630  -
RT16-4 400V 1250 700,800,1000,1250 400V
100kA
≤110 3400 2480
Outline and installation
Main technical parameter
Type RT16-00 RT16-0 RT16-1 RT16-2 RT16-3 RT16-4(RT17)
a 78.5 125 135 150 150 200
b 29 29 48 58 67 85
c 57 57 62 72 85 115
d 49 67 67 67 67 87
e 6 6 6 6 6 8
A 30 30 58 60 60 100
B 120 170 200 250 250 300
C1 61 73 83 99 105 150
C2 85 93 96 112 120 170
D 100 150 175 200 210 260
E 25 25 25 25 25 30
F 7.5 7.5 10.5 10.5 10.5 13
G -- -- 30 30 30 40
Fuse-carrier
Mainly used to assemnble and change RT16 senes low-voltage high breaking fuses in the circuit
of rated voltage up to 1000V.
NH00 NH1 NH2
NH00 NH1 NH2
NH3 NH00-BASE NH1-BASE
NH2-BASE NH3-BASE NH00-3PBASE
RT14 Series cylinder cap fuse
RT14-10Φ10×25
RT14-16Φ8.5×31
RT14-20Φ10×38
RT14-32Φ14×51
RT14-63Φ22×58
RT14-125Φ30×58
Scope of application
    It is applicable distributing equipment in indusrtial electrial distributing installation of AC50Hz(or60Hz) rated voltage 400V ,rated current 63A and below.against damage due to overload or short eircuit.
Type and meaning
Main technical parameter
Type Rated voltage Rated cuttent  Rated breaking capacity Rated power dissipation of fuse-link Weight of Holder Weight of fuse-link
Holder Fuse-link     l1 kA COSφ
RT14-10 500V 2,4,6,8,10 100 0.1~0.2 ≤3 4
RT14-16 2,4,6,8,10,12,16 ≤3 6
RT14-20 20 2,4,6,8,10,12,16,20 ≤3 40 8
RT14-32 32 2,4,6,8,10,12,16,20,25,32 ≤5 155 20
RT14-63 63 16,20,25,32,40,50,63 ≤9.5 240 55
Outline and installation

1、The outline size of the fuse-link see the following map and table
Type Size L C Hmax
RT14-10 10×25 25±0.6 10.3±0.1 10.5
RT14-16 8.5×31 31±0.8 8.5±0.1 13.8
RT14-20 10×31 38±0.6 10.3±0.1 16.2
RT14-32 14×51
51 +0.6
-0.1
14.3±0.1 16
RT14-63 22×58
58 +0.1
-2.0
22.2±0.1 13.5
2、The outline installation size of the holder of the fuse see the following map
RT14-20 Φ10×38 RT14-32 Φ14×51 RT14-63 Φ22×58
AM1 Φ8.5×31 AM3 Φ14×51 AM4 Φ22×58
FS-100 Φ30×58 FB14 Φ8.5×31 HG30-63/3P Φ14×51
RT-63 Φ14×51 RT-125 Φ22×58 RT-125 Φ22×58
RT18 Series cylinder cap fuse
RT18-32Φ10×38
RT18-63Φ14×51
RT18-32/1P
RT18-32/2P
RT18-32X/3P
RT18-63/1P
RT18-63/2P
RT18-63/3P
Scope of application
    It is applicable distributing equipment in indusrtial electrial installation of AC50Hz(or60Hz) rated voltage 500V ,rated current 63A and below.against damage due to overload or short eircuit.
Type and meaning
Main technical parameter
Type Rated voltage Rated cuttent Rated breaking capacity Rated power dissipation of fuse-link Weight of Holder Weight of fuse-link
Holder Fuse-link    l1 kA COSφ
RT18-32 500V 32 2,4,6,8,10,12,16,20,25,32 63 100 0.1~0.2 ≤3 82 8
RT18-63 63 2,4,6,8,10,12,16,
20,25,32,40,50,63
≤5 206 20
RT18A-32 32 2,4,6,8,10,12,16,20,25,32 ≤3 82 8
Outline and installation
1、The outline size of the fuse-link see the following map and table
Type Size L C Hmax
RT18-32 10×38 38±0.6 10.3±0.1 10.5
RT18-63 14×51
51 +0.6
-0.1
14.3±0.1 13.8
2、The outline installation size of the holder of the fuse see the following map
Type A B C D E F G
RT18-32 63 60 79 35 80 18 54
RT18-63 78 76 103 35 110 25 75
     
E31/1P Φ10×38 E31/2P Φ10×38 E31/3P Φ10×38
RL6 series screw-type fuse
E16  RL6-16
E27  RL6-25
E33  RL6-63
E16  RL6-16
E27  RL6-25
E33  RL6-63
E27 3J  RL6-25 3J
E33 3J  RL6-63 3J
Scope of application
    It is applicable cricuit of AC50Hz(60Hz), rated voltage up to AC500V, rated current up to 63A used for funtion of the protection against short citucit or overload for electrical installation.
Type and meaning
Main technical parameter
Type Rated voltage Rated cuttent Rated breaking capacity Rated power dissipation of fuse-link Weight of Holder Weight of fuse-link
Holder Fuse-link    l1 kA COSφ
RL6-16 500V 16 2,4,5,6,10,16,20,25 80 0.1~0.2 ≤5 95 40
RL6-25 25 2,4,5,6,10,16,20,25 ≤7.5 120 52
RL6-63 63 30,35,40,50,63 ≤15 155 71
Outline and installation
1、The outline size of the fuse-link see the following map and table
Type RL6-16 RL6-25 RL6-63
2-6 10 16 20-25 2-6 8-10 16 20 25 30-40 50 60-63
A 50 50
B 12.5 21 27
C 11.3 13 20
D 6 8 10 12 6 8 10 12 14 16 18 20
2、The outline installation size of the holder of the fuse see the following map
RL8(DO)Series screw-type fuse
D01 RL8-32
D02 RL8-63
D03 RL8-100
 
D02/32
D02/63
D02/63/N
D02-63/3P
Scope of application
    It is applicable cricuit of AC50Hz(60Hz), rated voltage up to AC500V, rated current up to 63A used for funtion of the protection against short citucit or overload for electrical installation.
Type and meaning
Main technical parameter
Size Rated current  Dimensions
d h
RL6-16(DO1) 2-16A 11 36
RL6-32(DO2) 20-63A 15 36
RL6-63(DO3) 80-100A 22 43
RO19、RO20 Series
RO19A
Φ20.5×76
RO19A
Φ20.5×76
RO19A
Φ20.5×76
Main technical parameter
Type Rated voltage(V) Rated cuttent
RO19A 250/600 0.5,1,2,4,6,10,16,20,25,32
RO19B 250/600 0.5,1,2,4,6,10,16,20,25,32
RO19 250/600 0.5,1,2,4,6,10,16,20,25,32
RO19C 250/600 0.5,1,2,4,6,10,16,
20,25,30,40,50,63
RO19D 250/600 0.5,1,2,4,6,10,16,
20,25,30,40,50,63
RO20A 250/600 60,70,75,80,100
RO20 250/600 30,40,50,60,80,100
RO20B 250/600 100,125,160,200
RO20C 250/600 60,80,100,125,160,200
RO20D 250/600 200,250,300,350,400
RO20E 250/600 100,160,200,250,300,400
RO20F 250/600 400,450,500,600
RO20G 250/600 200,250,300,400,500,6000
Outline and installation
Type A B C D
RO19A 76 20.5 - -
RO19B 114 20.5 - -
RO19 127 20.5 - -
RO19C 139 27 - -
RO19D 147 27 - -
RO20A 149 27 3 19
RO20 200 34 3 19
RO20B 181 40 5 28
RO20C 244 46 5 28
RO20D 219 53 6 41
RO20E 295 66 6 41
RO20F 264 66 6 51
RO20G 340 80 6 51

HRC Series connecting bolt type fuse
HRC-20
HRC-32
HRC-63
HRC-100
HRC-200
HRC-32
Scope of application
    HRC series bolting fuse is applicable for line overload or short-citcuit protection in low voltage distribution system of AC 50Hz, rated voltage AC415V and rated current up to 400A.
    Rated breaking capability 80KA
    Function grade: gG
    Executive standard: IEC269-1 IEC269-2
    GB13539.1 GB13539.2
Main technical parameter
Type Rated voltage(V) Rated cuttent weight(kg)
HRC-20(RG0) 415 2.4.6.10.16.20 0.015
HRC-32(RG1) 20.25.32 0.06
HRC-63(RG2) 32.40.50.63 0.08