LC1-D,LC1-K,LC1-F AC Contactor |
| Name : |
LC1-D,LC1-K,LC1-F AC Contactor |
| Type : |
AC Contactor & Thermal Relay |
| Description : |
|

| LC1-D09 |
LC1-D25 |
LC1-D65 |
LC1-D115 |
LC1-D150 |
| LC1-D170 | |
| LC1-D series AC
contactor is suitable for using in the circuit up to the rated
voltage 660V AC 50Hz or 60Hz, rated current 95A, for making,
breaking, frequent starting & controlling the AC motor. Combined
with the auxiliary contact block, air delay contactor,
mechanical interlocking contactor, star-delta starter. With the
thermal relay, it is combined into the electromagnetic starter.
The contactor is produced according to ICE158-1, VDE0660 &
BS5432. |
| volts(vac) |
24 |
42 |
48 |
110 |
220/230 |
230 |
240 |
380/400 |
400 |
415 |
440 |
500 |
660 |
| 50Hz |
B5 |
D5 |
E5 |
F5 |
M5 |
P5 |
U5 |
Q5 |
V5 |
N5 |
R5 |
S5 |
Y5 |
| 60Hz |
B5 |
D6 |
E6 |
F6 |
M5 |
- |
U6 |
Q6 |
- |
- |
R6 |
- |
- |
| 50/60Hz |
B7 |
D7 |
E7 |
F7 |
M7 |
P7 |
U7 |
Q7 |
V7 |
N7 |
R7 |
- |
- |
Specification
| Type |
LC1-009 |
LC1-012 |
LC1-018 |
LC1-025 |
LC1-032 |
Rated working current (A) |
AC3 |
9 |
12 |
18 |
25 |
32 |
| AC4 |
3.5 |
5 |
7.7 |
8.5 |
12 |
AC3 capacity of phase 3 squirrel-cage
motor AC3(KW) |
220V |
2.2 |
3 |
4 |
5.5 |
7.5 |
| 380V |
4 |
5.5 |
7.5 |
11 |
15 |
| 415V |
4 |
5.5 |
9 |
11 |
15 |
| 440V |
4 |
5.5 |
9 |
11 |
15 |
| 660V |
5.5 |
7.5 |
10 |
15 |
18.5 |
| Rated heat current (A) |
20 |
20 |
32 |
40 |
50 |
| electrical life |
AC4x10e4 |
20 |
20-15 |
20-7 |
15-7 |
15-7 |
| AC3x10e6 |
2 |
2 |
2 |
2 |
2 |
| Mechanical life x 10e6 |
20 |
20 |
20 |
20 |
20 |
| number of the contact |
3P+NO |
| 3P+NC |
| Type |
LC1-040 |
LC1-050 |
LC1-065 |
LC1-080 |
LC1-095 |
Rated working current (A) |
AC3 |
40 |
50 |
65 |
80 |
95 |
| AC4 |
18.5 |
24 |
28 |
37 |
44 |
AC3 capacity of phase 3 squirrel-cage
motor AC3(KW) |
220V |
11 |
15 |
18.5 |
22 |
25 |
| 380V |
18.5 |
22 |
30 |
37 |
45 |
| 415V |
22 |
25 |
37 |
45 |
45 |
| 440V |
22 |
30 |
37 |
45 |
45 |
| 660V |
30 |
33 |
37 |
45 |
45 |
| Rated heat current(A) |
60 |
80 |
80 |
125 |
125 |
| electrical life |
AC4x10e4 |
10-7 |
7 |
7-6 |
7-5 |
7-5 |
| AC3x10e6 |
2 |
2 |
1.6 |
1.6 |
1.6 |
| Mechanical life x 10e6 |
20 |
20 |
20 |
10 |
10 |
| number of the contact |
3P+NC+NO |
LC1-K AC Contactors
Technical parameter 1、the
main technical performance guideline of contactors table 1,table
2 2、the voltage of the contactors loop are
24V、36V、48V、110V、220V、380V for AC, 12V、24V、48V、110V、220V for DC
Note: for special voltage specification, please discuss with us
for doing 3、Action character: the close voltage for AC is
85-110%Us,release voltage is 20-75%Us; the close voltage for DC
is 80-110%Us,release voltage is 10-75%Us. |
|
|
Parameter\Type |
LC1-K06 |
LC1-K09 |
LC1-K12 |
|
rating working
voltage(V) |
660(990) |
|
rating working current
(A) |
380V |
AC-3 |
6 |
9 |
12 |
|
AC-4 |
2.6 |
3.5 |
5 |
|
Appoint heating
current(A) |
16 |
16 |
20 |
|
the max current when
turn on(A) |
380V |
60 |
90 |
120 |
|
660V |
72 |
108 |
144 |
|
the max current for
turn off (A) |
380V |
48 |
72 |
96 |
|
660V |
60 |
90 |
120 |
|
three phases cage
motors power which can be pulled AC3(KW) |
220v |
1.5 |
2.2 |
3 |
|
380v |
2.2 |
4 |
5.5 |
|
660v |
3 |
5.5 |
7.5 |
|
operation frequency
Time/h |
electricity life |
AC-3 |
1200 |
|
AC-4 |
300 |
|
electricity life Ten
thousand times |
AC-3 |
100 |
|
AC-4 |
20 |
|
machinery life |
Ten thousand times
|
1000 |
|
AC loop electricity
loss(W) |
2 |
|
DC loop electricity
loss(W) |
4 |
|
the section of
connection guideline(mm2) |
1.5 |
|
matched fuse machine
type |
NTOO-16 |
|
standard |
GB-14048.4 | |
The appearance and size of
installation |
|
|
|

| LC1-F115 |
LC1-F630 |
LC1-F780 |
| LC1-F150 | |
| LC1-F series AC
contactor is applicable to the circuits up to the rated voltage
1000V AC 50Hz or 60Hz,rated current up to 780A,for long distance
breaking circuit and frequently starting or controlling the
motor. It also can be used for the control of distribution
circuits of rated current from 200A to 1600A. |
Specifications
| Type |
LC1-F115 |
LC1-F150 |
LC1-F185 |
LC1-F225 |
LC1-F265 |
LC1-F330 |
LC1-F400 |
LC1-500 |
LC1-F630 |
| Rated
operation current (A) |
AC-3 |
115 |
150 |
185 |
225 |
265 |
330 |
400 |
500 |
630 |
| AC-1 |
200 |
250 |
275 |
315 |
350 |
400 |
500 |
700 |
1000 |
| Standard
power ratings of 3-phase motors AC-3(KW) |
220/230V |
30 |
40 |
55 |
63 |
75 |
100 |
110 |
147 |
200 |
| 380/400V |
55 |
75 |
90 |
110 |
132 |
160 |
200 |
250 |
335 |
| 415V |
59 |
80 |
100 |
110 |
140 |
180 |
200 |
280 |
375 |
| 440V |
59 |
80 |
100 |
110 |
140 |
200 |
250 |
295 |
400 |
| 500V |
75 |
90 |
110 |
129 |
160 |
200 |
257 |
355 |
400 |
| 660/690V |
80 |
100 |
110 |
129 |
160 |
200 |
280 |
335 |
450 |
| 1000V |
65 |
65 |
100 |
100 |
147 |
160 |
185 |
335 |
45 |
LC2-D LC2-F Mechanical
Interlocking Contactors
|
.
|
| Specificaton |
|

| |